Rosemount 3051C Coplanar Pressure Transmitter Overview
Rosemount 3051 Pressure Transmitter for Differential, Gauge, and Absolute Measurement
The coplanar design is what allows the 3051C to mount directly to manifolds, remote seals, and flow primary elements without extra adapters, and to be supplied with a 150:1 rangedown, so one transmitter rated for a wide span can also accurately measure a much narrower one. Reference accuracy of up to 0.04 percent of span and 10-year stability of 0.2 percent of URL keep readings dependable well past a typical recalibration cycle.
This is proven, high-volume technology. Emerson reports more than 10 million Rosemount 3051 family devices installed worldwide across three decades of production, and the coplanar platform remains the reference point buyers compare every other pressure transmitter against.
Choosing a Rosemount 3051 Pressure Transmitter
Most people looking for a Rosemount 3051 want this coplanar version, the body you see on orifice runs and level legs. If your process connection is a single threaded port rather than a flange, look at the in-line Rosemount 3051T instead. If you need tighter accuracy, a longer warranty or multivariable mass flow, the Rosemount 3051S is the step up. Where a 3051 pressure transmitter is more than the job needs, the Rosemount 2051C uses the same coplanar mounting at a lower price.
Send us the model string from the nameplate, or from the Rosemount 3051 datasheet or manual, and we read it back to you before quoting: transmitter type (CD, CG or CA), range code, output, materials, housing and approvals. That way a replacement Rosemount 3051 differential pressure transmitter arrives set up to drop into the existing loop, including when it replaces an obsolete Rosemount 1151. See the full Rosemount transmitter range.
Sensing Principle
Measures
Reference Accuracy
Output Protocols
Need pricing for the 3051C?
3051C Measurement Configurations
The three measurement configurations of the 3051C Coplanar Pressure Transmitter
3051CD
Rosemount 3051C Differential Pressure Transmitter
3051CG
Rosemount 3051C Gauge Pressure Transmitter
3051CA
Rosemount 3051C Absolute Pressure Transmitter
3051C Base Model Numbers
3051C , base model numbers
| Model | Type | Status |
|---|---|---|
| Rosemount 3051CD | Differential Pressure | Available to Order |
| Rosemount 3051CG | Gauge Pressure | Available to Order |
| Rosemount 3051CA | Absolute Pressure | Available to Order |
Applications
3051C applications
Oil, Gas & Petrochemical
Power Generation
Chemical Processing
Water & Wastewater
Preventative Maintenance
Explosive or Hazardous Areas
Regions We Serve
Where Instrubiz Supports the 3051C in Canada
Alberta
Ontario
Browse by Category
This product is part of the Rosemount Pressure Transmitters category
This Product's Category
Rosemount Pressure Transmitters
Other Products in This Category
Browse Other Categories
Bently Nevada Proximity Sensors
Bently Nevada Vibration Monitoring
Bently Nevada Inertial Sensors
Request Pricing & Availability
Request a quote for the 3051C
- We confirm your part number and configuration within 24 hours
- We provide pricing and current stock availability
- We confirm shipping timeline to your location
Prefer to reach us directly?
Why Choose Instrubiz
Supplying the 3051C to Canadian industry
Best Prices Guaranteed
Efficient Lead Times
Duty-Paid Delivery
FAQ
What Buyers Ask About the 3051C
It measures differential, gauge, or absolute process pressure using a coplanar sensor body, and converts that reading into a 4-20 mA HART, Fieldbus, or wireless output for flow, level, and pressure monitoring across process, power, and manufacturing operations.
The 3051C uses a coplanar flange with both isolating diaphragms on one side, which allows it to be ordered as a differential, gauge, or absolute transmitter and to mount directly to manifolds and flow elements. The 3051T uses an in-line, threaded process connection instead, suited to tighter installation spaces where a coplanar flange will not fit. We can help confirm which configuration your application needs. See the Rosemount 3051T page for in-line ranges up to 20,000 psi.
The 3051S is Rosemount’s next-generation coplanar platform, built on the same coplanar principle as the 3051C but adding expanded diagnostics and a modular platform architecture. The 3051C remains Emerson’s high-volume, currently produced coplanar transmitter and is not a legacy or discontinued model.
Each 3051C is ordered and configured for one measurement type. The coplanar platform allows the same body design to be built as any of the three, but the specific unit shipped is configured for the measurement type ordered.
Yes. The 3051 family is Rosemount’s current, actively produced pressure transmitter platform, with more than 10 million units installed worldwide. Contact our team with the specific configuration to confirm current stock availability.
Yes, duty-paid, door-to-door delivery is available across Canada, with particular experience serving oil & gas and petrochemical operations in Alberta and manufacturing facilities in Ontario.
For the fastest quotation, provide the measurement type needed (differential, gauge, or absolute), the pressure range, quantity required, and delivery location. Our team confirms configuration and pricing within 24 hours.
Calibration on a 3051 is usually two steps. A sensor trim (a zero trim, or a full trim against a pressure standard) corrects the digital pressure reading, and an analog output trim matches the 4-20 mA signal to your control system. Both are done with a HART communicator or asset management software. On a DP unit, do the zero trim with both sides equalized at the manifold.
Process pressure pushes on the isolating diaphragms, and fill fluid carries that pressure to a sensing diaphragm in the centre of the sensor. As the sensing diaphragm moves, the capacitance on each side changes. The electronics turn that change into a pressure value, correct it for temperature, and send it out as 4-20 mA HART, FOUNDATION Fieldbus or WirelessHART.
Need help selecting a Rosemount 3051 configuration?
Tell us your application and we’ll confirm the right components, same day.