Genuine Parts for Saudi Industry

Dräger Pac 6000 Single Gas Detector

Switch it on, clip it to your collar and forget about it for two years. That is the whole idea behind the Dräger Pac 6000: one gas, one alarm, and no charging, calibration or spare parts to worry about.

We supply it as an H2S gas detector to oil and gas crews, and in CO, O2 and SO2 versions to plants, utilities and contractors across Saudi Arabia. Send us the gas and quantity, and we will reply with a price and a delivery date.

Competitive Pricing

Genuine products, fair market rates

Fast Quotations

Clear stock & lead-time answers

Delivery Across Saudi Arabia

Riyadh, Eastern Province, Jeddah and beyond

Product Overview

What the Dräger Pac 6000 Is, and Who It Suits

Most gas incidents on a site are not caused by a lack of detectors. They happen because a detector was flat, overdue for service, or left in the truck because it was a nuisance to carry. The Pac 6000 was designed around that problem. It is small enough to wear all day, it has no battery to charge, and it keeps working for two years from the day it is activated. After that, you replace it with a new one.

Each unit watches one gas. On Saudi oil and gas sites that is almost always hydrogen sulphide, so most of the units we ship are the H2S version. The same body is also made for carbon monoxide, oxygen and sulphur dioxide. If you see it written as Draeger Pac 6000 or Drager Pac 6000, it is the same instrument. The spelling simply depends on the keyboard.

Who buys it? Mainly three groups. Contractors and shutdown teams who need to put a detector on a large crew quickly. Operators who would rather replace a fleet every two years than manage sensor changes and service records. And safety managers who want a simple backup H2S detector for visitors, drivers and anyone who only passes through a hazardous area now and then.

It is not the right choice for everyone. If your team needs to measure several gases at the same time, for example before entering a tank, you will want a multi gas detector instead. If you prefer to keep the same instrument for many years and service it yourself, look at the Pac 6500, which has a replaceable sensor and battery. We are happy to talk through which one fits the job.

GasesH2S / CO / O2 / SO2
Operating Life2 years from activation
ProtectionIP68
TypePersonal, disposable
Dräger Pac 6000 Single Gas Detector

Looking for a Dräger Pac 6000 price in Saudi Arabia?

Request a Quote

Key Features

Why Crews Like This H2S Gas Detector

  • Nothing to charge, swap or service for two full years
  • Light enough to wear on a collar or chest pocket through a 12-hour shift
  • Sealed to IP68, so desert dust, washdowns and rain are not a problem
  • Loud alarm, bright flashing lights and a vibration alert you feel through clothing
  • Screen shows the live reading and how much operating time is left
  • Quick bump test with a gas cylinder or a Dräger bump test station
  • Event log you can download for incident reports and audits
  • Approved for use in potentially explosive areas (check the exact marking on the datasheet)

Specifications

Dräger Pac 6000 Technical Specifications

SpecificationValue
Gas (one per unit)H2S, CO, O2 or SO2
Detector typePersonal single-gas monitor, disposable
Operating life2 years from activation
Measuring range, H2S0 to 100 ppm
Measuring range, CO0 to 2,000 ppm
Measuring range, O20 to 25 vol%
Measuring range, SO20 to 20 ppm
Ingress protectionIP68
AlarmsAudible, visual and vibration
MaintenanceNone required during operating life

Models & Part Numbers

Gas Versions & Part Numbers

Each unit is built for one gas, so pick the version that matches your main hazard. You can mix versions on one order, for example H2S units for field crews and O2 units for your confined-space team. Not sure of the part number? Tell us the gas and we will match it.

ModelPart No.GasStatus
H2S version83 26 320Hydrogen sulphideAvailable to Order
CO version83 26 321Carbon monoxideAvailable to Order
O2 version83 26 322OxygenAvailable to Order
SO2 version83 26 323Sulphur dioxideAvailable to Order

Applications

Where It Is Used in Saudi Arabia

Oil & Gas Fields

Sour gas is a daily risk on many Eastern Province fields. Rig crews, well testers and pipeline teams wear the H2S version as their personal alarm, alongside the fixed detection on the facility.

Refineries & Petrochemicals

During turnarounds a plant can take on hundreds of extra workers in a week. A detector that needs no setup or charging makes it far easier to equip everyone properly from day one.

Water & Wastewater

Hydrogen sulphide collects in sewers, lift stations and sludge areas, often in low spots where nobody expects it. Utility crews use the H2S model as a simple first line of protection.

Confined Space Work

The O2 version warns when oxygen drops below a safe level inside tanks, vessels and pits. For entries with several possible hazards, pair it with a multi gas detector.

Industrial Plants & Warehouses

The CO version suits areas with engines, furnaces, forklifts or generators, where carbon monoxide can build up in enclosed spaces.

Contractors & Visitors

Hand one to a driver, an inspector or a visiting engineer at the gate. There is nothing to teach beyond a two-minute briefing on what the alarms mean.

Why Choose Instrubiz

Supply & Delivery in Saudi Arabia

Genuine Products

We supply genuine brand-name instruments and safety equipment, with the correct part numbers confirmed before you order.

Clear Lead Times

Availability varies by product and quantity. We give you a clear lead time with every quote and support urgent shutdown needs.

Delivery Across the Kingdom

We deliver to sites in Riyadh, the Eastern Province (Dammam, Al Khobar, Jubail), Jeddah and other regions of Saudi Arabia.

FAQ

Dräger Pac 6000 Questions We Get Asked

How long does the Dräger Pac 6000 last?

Two years from the day it is activated. During that time there is no battery to change and no sensor to replace. The screen counts down the time left, so you can order replacements before the units expire.

How much does the Dräger Pac 6000 cost in Saudi Arabia?

The price depends on the gas version, how many units you need and where they are going. Send us those three details and we will reply with a quote in Saudi riyals and a realistic delivery date.

Is a single gas detector enough, or do I need a multi gas detector?

If one gas is the main danger where people work, such as H2S on a sour-gas site, a single gas detector is usually enough and much easier to manage. If people enter tanks, pits or other confined spaces where oxygen, flammable gas and toxic gas can all be a problem, a multi gas detector is the safer choice.

How do you bump test an H2S gas detector?

You expose it briefly to a known amount of H2S test gas and check that the reading rises and every alarm goes off. With the Pac 6000 this takes under a minute using a test gas cylinder and adapter, or you can use a Dräger bump test station, which runs the test and saves the result for your records.

Does the Pac 6000 need calibration?

Not during its two-year life. Most site safety rules still call for a bump test before use, to prove the sensor and alarms work. If your own procedure requires a calibration, it can be done with test gas and Dräger PC software.

What does ppm mean on a gas detector?

It stands for parts per million, the unit used for toxic gases like H2S, CO and SO2. A reading of 10 ppm H2S means 10 parts of hydrogen sulphide in every million parts of air. The O2 version shows oxygen as a percentage of the air instead.

What is the difference between the Pac 6000 and the Pac 6500?

The Pac 6000 is disposable and runs for a fixed two years. The Pac 6500 is reusable, with a replaceable sensor and battery and no fixed end date. Choose the 6000 for low effort and the 6500 if you prefer to keep and service your instruments.

What happens when the two years are over?

The unit stops working as a detector and should be disposed of under your local electronic waste rules. Many of our customers place a repeat order a few weeks before the end date so there is never a gap on site.

Do you deliver across Saudi Arabia?

Yes. We deliver to Riyadh, Dammam, Al Khobar, Jubail, Jeddah and other cities. Lead time depends on the gas version and quantity, and we confirm it with every quote. For shutdowns and urgent jobs, tell us your date and we will tell you honestly whether we can meet it.

Request Pricing & Availability

Request a Quote for the Dräger Pac 6000 Single Gas Detector

Send us the gas version, quantity and delivery city. We reply with pricing, availability and lead time.

  1. We confirm the part number and gas version
  2. We send pricing and current availability
  3. We confirm the delivery timeline to your site






    Scroll to Top