Genuine Parts for Saudi Industry

Dräger X-am 5100 Single Gas Detector

Some gases are too reactive for an ordinary sensor. Hydrogen fluoride, hydrogen chloride, hydrogen peroxide and hydrazine stick to surfaces, attack materials and can be deadly at very low levels. The Dräger X-am 5100 is a portable gas detector built for exactly these gases.

We supply the X-am 5100 to refineries, aluminium and glass plants, chemical sites and laboratories across Saudi Arabia. Tell us which gas you need to watch, and we will confirm the right sensor, price and delivery.

Competitive Pricing

Genuine products, fair market rates

Fast Quotations

Clear stock & lead-time answers

Delivery Across Saudi Arabia

Riyadh, Eastern Province, Jeddah and beyond

Product Overview

What the Dräger X-am 5100 Is, and Who It Suits

Most personal gas detectors are designed for H2S, CO, oxygen and flammable gas. They are not built for acids and highly reactive chemicals. These gases can be absorbed by plastic parts before they reach the sensor, so a normal detector may read too low or too late. The X-am 5100 uses a housing and sensors designed to handle these substances.

Each unit carries one sensor. The main versions are for hydrogen fluoride (HF), hydrogen chloride (HCl), hydrogen peroxide (H2O2) and hydrazine. As an HF gas detector it is used in refinery alkylation units, aluminium smelters and glass etching. The HCl version suits pickling lines and chemical plants, hydrogen peroxide is common in pulp and food processing, and hydrazine is used in power plant water treatment and some aerospace work. You may also see it written as Draeger X-am 5100 or Xam 5100.

It is a robust instrument made for industrial use, larger than the Pac detectors and powered by batteries that are easy to change on site. It can be worn on a belt or clipped close to the breathing zone, and it can also be used for checks before entering a confined space where one of these gases may be present.

The X-am 5100 is a specialist detector. If your hazard is H2S, CO or oxygen, a Pac detector is smaller and cheaper. If you need flammable gas and several toxic gases together, a multi gas detector is the better fit. Choose the X-am 5100 when the risk is one of the reactive gases above and you need a reading you can rely on.

Because these gases are so dangerous at low levels, we always check the details before quoting: which gas, what concentrations you expect, whether the detector is for personal wear or for checks before work starts, and which exposure limits apply on your site. That way you get a sensor and accessories that suit how the detector will actually be used.

GasesHF / HCl / H2O2 / Hydrazine
SensorReplaceable, one gas
ProtectionIP67
TypePersonal, portable
Dräger X-am 5100 Single Gas Detector

Need a Dräger X-am 5100 price in Saudi Arabia?

Request a Quote

Key Features

Why Specialist Sites Choose This Portable Gas Detector

  • Designed for reactive gases that ordinary detectors handle poorly
  • Sensor versions for HF, HCl, hydrogen peroxide and hydrazine
  • Replaceable sensor, so the detector can be switched to another gas
  • Easy-to-change batteries for long shifts on site
  • Robust housing protected against dust and water
  • Loud alarm, bright lights and vibration alert
  • Data logger for exposure records and incident reviews
  • Approved for use in potentially explosive areas (check the exact marking on the datasheet)

Specifications

Dräger X-am 5100 Technical Specifications

SpecificationValue
Gas (one per unit)HF/HCl, H2O2 or hydrazine (confirm full sensor list on datasheet)
Detector typePersonal and portable single gas detector
SensorReplaceable Dräger XS sensor
PowerReplaceable batteries
Measuring rangesDepend on the sensor fitted, see datasheet
Ingress protectionIP67
AlarmsAudible, visual and vibration
DataData logger, read out with Dräger PC software
TestingBump test with the matching test gas, see Dräger guidance for reactive gases
Hazardous area approvalSee datasheet for the exact marking

Versions

Sensor Versions

The X-am 5100 is ordered by sensor. These are the versions we are asked about most. If your gas is not listed, ask us and we will check whether Dräger has a matching sensor.

ModelPart No.GasStatus
HF / HCl versionHydrogen fluoride and hydrogen chlorideAlkylation units, smelters, glass etching, picklingAvailable to Order
H2O2 versionHydrogen peroxidePulp, food and beverage, sterilisationAvailable to Order
Hydrazine versionHydrazinePower plant water treatment, aerospaceAvailable to Order

Applications

Where It Is Used in Saudi Arabia

Refinery Alkylation Units

An HF gas detector for operators and maintenance staff around hydrofluoric acid alkylation units, especially during maintenance and line breaks.

Aluminium & Metal Plants

Hydrogen fluoride is released in aluminium smelting. Staff in potlines and fume treatment areas use the HF version as personal protection.

Chemical & Pickling Plants

The HCl version protects workers around acid storage, steel pickling lines and chemical processes in Jubail and Yanbu.

Glass & Electronics

A hydrogen fluoride detector for etching and cleaning areas in glass, solar and electronics production.

Power & Desalination

The hydrazine version is used where hydrazine treats boiler feed water in power and desalination plants.

Pulp, Food & Sterilisation

The hydrogen peroxide version suits bleaching, aseptic packaging and sterilisation areas.

Why Choose Instrubiz

Supply & Delivery in Saudi Arabia

Genuine Products

We supply genuine brand-name instruments and safety equipment, with the correct part numbers confirmed before you order.

Clear Lead Times

Availability varies by product and quantity. We give you a clear lead time with every quote and support urgent shutdown needs.

Delivery Across the Kingdom

We deliver to sites in Riyadh, the Eastern Province (Dammam, Al Khobar, Jubail), Jeddah and other regions of Saudi Arabia.

FAQ

Dräger X-am 5100 Questions We Get Asked

Which gases does the Dräger X-am 5100 detect?

One gas per unit, from a range of reactive gases. The main versions are hydrogen fluoride and hydrogen chloride, hydrogen peroxide, and hydrazine. Tell us your gas and we will confirm the right sensor.

How much does the Dräger X-am 5100 cost in Saudi Arabia?

The price depends on the sensor, the quantity and the delivery city. Send us those details and we will reply with a quote in Saudi riyals and a clear lead time.

Why can't I use a normal gas detector for HF?

Hydrogen fluoride and similar gases are very reactive. They can be absorbed by ordinary detector housings and filters before they reach the sensor, so the reading may be too low or too slow. The X-am 5100 is designed to handle these gases.

Can the X-am 5100 be used for confined space entry?

It can be used for checks before and during entry where one of its target gases may be present. For confined spaces you also need oxygen, flammable gas and common toxic gas checks, so it is usually used alongside a multi gas detector.

Is the X-am 5100 a portable gas detector or a fixed one?

It is portable. It is worn on the body or carried by hand. For permanent monitoring of HF or HCl in a fixed location, a fixed gas detection system is the right choice, and we can advise on that too.

What is the difference between an HF gas detector and a normal toxic gas detector?

An HF gas detector uses a sensor made to react to hydrogen fluoride and a housing that does not absorb it. A normal toxic gas detector is built for gases like H2S and CO, and may not respond correctly to HF at all. For hydrogen fluoride work, always use a detector that is specified for HF.

How do you bump test the X-am 5100?

Bump testing reactive gases needs the right test gas and equipment, because the gases themselves are hard to handle. Follow Dräger's guidance for your sensor version. We can help you find the correct test gas and adapters.

Can I change the sensor later?

Yes. The sensor is replaceable, so the detector can be switched to another gas if your needs change. The new sensor must be set up and calibrated before use.

Is it approved for hazardous areas?

Yes, it is approved for use in potentially explosive atmospheres. Please check the exact marking on the datasheet against your site requirements, and we can confirm it before you order.

Do you deliver across Saudi Arabia?

Yes. We deliver to Riyadh, Dammam, Al Khobar, Jubail, Yanbu, Jeddah and other cities. Lead time depends on the sensor and quantity, and we confirm it with every quote.

Request Pricing & Availability

Request a Quote for the Dräger X-am 5100

Send us the gas version, quantity and delivery city. We reply with pricing, availability and lead time.

  1. We confirm the part number and gas version
  2. We send pricing and current availability
  3. We confirm the delivery timeline to your site






    Scroll to Top